Heat recovery from greasy waste air in the food industry
Waste air from steam peelers and fryers contains fats and a lot of heat. The spray tunnel copes with both.
Heat from the waste air

Waste air from steam peelers or fryers flows through a FERCHER spray tunnel, where water absorbs the heat. This significantly reduces natural gas or heating oil consumption.
Clean air

The fine spray mist washes out most coarse solids such as dust and lint. Depending on the substance, odours are reduced as well. The spray water also captures most of the fat and oil droplets carried in the air as aerosols. The achievable separation rate is determined in a trial.
Heat into clean service water

The spray water is contaminated afterwards. It therefore runs over a FERCHER FB wastewater heat exchanger, which transfers the heat to clean service water.
The units can also be installed outdoors. The intermediate medium must then be frost-proof.
Use
The service water is used in the production process, to preheat boiler feed water, or for space heating.

Example: food factory
An EST-D-1800 spray tunnel and an FB-12/WS wastewater heat exchanger use the waste air from a steam peeler at around 100 °C.
| Key figure | Value |
|---|---|
| Heat output | 261 kW |
| Operation | 16 hours a day, 260 days a year |
| Energy saved per year | 1,085,760 kWh |
| Investment, entire system, at the time | approx. €127,780 |
| Payback at the time | around 2 years at €0.40 to €0.50 per litre of heating oil, calculated with 8 kWh per litre |
What this heat is worth today
1,085,760 kWh saved per year, valued at current energy prices (indicative figure, not a commitment):
| Energy source replaced | Net price, as of November 2026 | Value per year |
|---|---|---|
| Natural gas | 10 ct/kWh | around €120,600 |
| Heating oil | 1.50 €/L | around €203,600 |
| Electricity (direct electric heating) | 23 ct/kWh | around €249,700 |
As of November 2026, rounded, excluding VAT. Calculated with typical boiler efficiencies: natural gas 90 %, heating oil 80 % (so 1 litre of heating oil supplies around 8 kWh of useful heat), electricity 100 %. Prices: household end-customer prices on energie.gv.at (Austria; heating oil of 26/10/2026, natural gas and electricity of 01/08/2026). Your prices may differ, and we are happy to calculate with your figures.
The figures come from individual installations and apply to their operating conditions. They are not a commitment for your installation. Only the quotation and order confirmation are binding.
Matching product
Waste air heat exchanger: EST energy spray tunnel
For waste air containing sticky, greasy or tar-like condensing substances: the spray tunnel uses water to extract the heat and scrub the air at the same time.
Learn more