Skip to content
FERCHER GmbHwww.fercher.at/en/
Heat exchangers from Austria, quality since 1988+43 676 606 95 40office@fercher.at
Request a calculationCall
Menu
EN

Heat recovery from dirty exhaust gas, wastewater and waste air – even where other heat exchangers clog

FERCHER heat exchangers are built for media that clog plate and shell-and-tube units: for exhaust gas up to 500 °C, wastewater with lint and particles, and sticky waste air. From a few kilowatts to the megawatt range, designed and manufactured in Austria since 1988.

Free of charge and non-binding. Replies usually within 1–2 working days.

FERCHER FW-600 exhaust gas heat exchanger

What would you like to use?

  • Exhaust gas and flue gas heat exchangers, FW series

    Exhaust gas and flue gas

    FW series

    Flat-tube exhaust gas heat exchangers, cleanable without removal, up to 500 °C, special steel up to 800 °C.

    Learn more
  • Wastewater heat exchangers, FB and AWT series

    Wastewater and cooling water

    FB and AWT series

    Heat exchangers with unpressurised film flow, even for extremely contaminated wastewater, heat pump ready.

    Learn more
  • Waste air heat exchanger: EST energy spray tunnel

    Waste air and process air

    EST series

    Filterless spray tunnel for sticky, greasy or lint-laden waste air. Recovers heat and scrubs the air.

    Learn more

9 mm instead of fine fins

Flat tubes for exhaust gas, free film flow for wastewater: dirt passes through instead of blocking the heat exchanger.

Easy to clean

Take off the covers and clean: no removal needed, and for wastewater even during operation.

Calculated free of charge

We use our own software to calculate output and pressure loss for your operating conditions.

Case studies with key figures

  • Food industry

    1,085,760 kWhenergy saved per year

    Spray tunnel and wastewater heat exchanger use the waste air from a steam peeler. At 10 ct/kWh natural gas (November 2026) around €120,600 a year.

    View case study
  • Heating plant

    252,000 kWhsaved per year, extrapolated

    FW-600 in the flue gas duct, flue gas from around 190 to 110 °C. At 10 ct/kWh natural gas (November 2026) around €28,000 a year.

    View case study
  • Municipal wastewater

    38 kWheating output from 8 °C wastewater

    Four exchanger elements and a heat pump. At 3,000 operating hours and 10 ct/kWh natural gas (November 2026) around €5,500 a year, after the heat pump's electricity.

    View case study

The figures come from individual installations and apply to their operating conditions. They are not a commitment for your installation. Only the quotation and order confirmation are binding.

A selection of our customers

  • Mercedes AMG
  • Fraunhofer Gesellschaft
  • BAYER Oy Turku
  • AVL List GmbH
  • Ottakringer Brauerei GmbH
  • Österreichisches Bundesheer
  • Kelag AG
  • Lamb Weston Meijer GmbH
  • and many more

From study to delivery

  • StudiesProcess diagrams, calculations and ROI on 10 to 20 pages.
  • CalculationSizing with our own software, free of charge and non-binding.
  • AdviceDirectly from the engineers who calculate your heat exchanger.
  • DeliveryStandard types and custom designs.

Learn more

FERCHER GmbH · St. Thomas 10 · 9400 Wolfsberg · Austria · +43 676 606 95 40 · office@fercher.at · www.fercher.at